Collection of natural gas samples
Natural gas sampling probes, SOCLEMA solutions
For the sampling of a representative gas sample, SOCLEMA offers you the following GENIE ® sampling probes.
With the technology of the Genie® membrane, these sampling probes guarantee that the fluids are allowed to be rejected in accordance with the standards API 14.1 and GPA 2166. To meet all possible configurations, the sampling probes are available in several references, the length of which can vary from 2 inches (for installation on a small depressurized line) to several feet (for installation Underground line that cannot be depressurized, for example).
GENIE GPHV sampling probe
- Probe for high velocity gas application
- Maximum working pressure: 310.3 barg (4500 psig)
- Maximum temperature: 149°C
- Maximum speed: 30m/s (4″) and 17m/s (10″)
- 2 lengths: 101.6 mm (4″) and 254 mm (10")
- No membrane
- No gas pressure reduction
- Connection: 1/2" NPT thread-o-let
- Installation on depressurized line
GENIE GPSD sampling probe
- Fixed probe for gas application and small diameter pipes
- Maximum working pressure: 206.8 barg (3000 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 132°C with type 7 membrane
- Length: 50.8 mm (2″)
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 3/4" NPT thread-o-let
- Installation of housing on depressurized line
- Extraction and insertion of probe under pressure for maintenance
GENIE GP2 sampling probe
- Fixed probe for gas application and small diameter pipes
- Maximum Working Pressure: 241.3 barg (3500 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- -37°C to 149°C with diaphragm type 7
- Length: 50.8 mm (2″)
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 3/4" or 1″ NPT thread-o-let
- Installation of housing on depressurized line
- Extraction and insertion of probe under pressure for maintenance
GENIE GPR sampling probe
- Fixed probe for gas application
- Maximum Working Pressure: 241.3 barg (3500 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 132°C with type 7 membrane
- 3 Lengths: 101.6 mm (4″); 177.8 mm (7″); 228.6 mm (9")
- Separation of liquids by membrane on probe tip
- Integrated gas pressure reduction
- Connection: 3/4" or 1″ NPT thread-o-let
- Installation of housing on depressurized line
- Extraction and insertion of probe under pressure for maintenance
GENIE 701 sampling probe
- Portable probe for gas application
- Maximum working pressure: 206.8 barg (3000 psig)
- Maximum temperature: -37°C to 85°C with diaphragm type 6
- Adjustable length up to a maximum length of 304.8 mm (12″)
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 1/2″ NPT full opening threaded valve
- Insertable/retractable probe under pressure
GENIE 702 sampling probe
- Fixed probe for gas application
- Maximum Working Pressure: 241.3 barg (3500 psig)
- Maximum temperature :
- -37.2°C to 85°C with type 6 membrane
- -37.2°C to 149°C with Type 7 membrane
- Maximum flow rate: 2 LPM with diaphragm type 6 and 2,5 LPM with diaphragm type 7
- Lengths on request from 304.8 mm (12″) to 3048 mm (120")
- Separation of liquids by membrane on probe tip
- Connection: 3/4″ NPT full-opening threaded or flanged valve
- Insertable/retractable probe under pressure
- Ball valve to partially retract the probe
GENIE 750 sampling rod
- Fixed probe for gas application
- Maximum Working Pressure: 258.6 barg (3750 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 149°C with type 7 membrane
- 6 lengths: 203.22 mm (8″), 304.8 mm (12″), 457.2 mm (18″), 609.6 mm (24″), 914.4 mm (36″) or 1219.2 mm (48″)
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 3/4″, 1″, or 1.5″ NPT full opening threaded or flanged valve
- Insertable/retractable probe under pressure
GENIE 755 sampling rod
- Fixed probe for gas application
- Maximum Working Pressure: 258.6 barg (3750 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 132°C with type 7 membrane
- 6 lengths: 203.22 mm (8″), 304.8 mm (12″), 457.2 mm (18″), 609.6 mm (24″), 914.4 mm (36″) or 1219.2 mm (48″)
- Separation of liquids by membrane on probe tip
- Integrated gas pressure reduction
- Connection: 3/4″, 1″, or 1.5″ NPT full opening threaded or flanged valve
- Insertable/retractable probe under pressure