A sampling system must carry out the operations that produce a representative sample. It therefore includes the following three main sampling steps :
- Collect a fraction of the process fluid at a conveniently chosen point to obtain a representative sample
- Condition The sample shall be conditioned to bring the physico-chemical characteristics of the process (temperature, pressure, humidity) to the values required for normal operation of the analyser. The conditioning must keep the representativeness of the sampleAvoid vaporization/condensation and sorption phenomena.
- Transfer the sample to the analyzer within a time period compatible with the operation of the process.
No sampling system is ideal or universal. It aims to find the best balance between all the sampling requirements for each installation.
SOCLEMA offers you different solutions for your biomethane sampling systems.
We present you with a sampling solution for biogas that has been installed on an existing station.