Extraction and Sampling of gas and liquid samples
GENIE | SOCLEMA sampling rod
SOCLEMA offers probes for the collection of gas and liquid samples for the natural gas, refining and petrochemical sectors.
Our sampling probes make it possible to take a representative sample with a wide choice of models and options to bring you the solution that fits your configuration: separation in the probe tip, length, connection, with or without gas pressure reduction, fixed or transportable, installable on depressurized line or under pressure ... All our models are easy to install and maintain.
To find out which sampling probe is best suited for your application, complete the form below. The information requested is essential to determine the type of probe that is right for you.
You can also consult the cane comparison table which will give you the main characteristics of each cane model.
GENIE GPHV sampling probe
- Probe for high velocity gas application
- Maximum working pressure: 310.3 barg (4500 psig)
- Maximum temperature: 149°C
- Max velocity: 30 m/s (4″) and 17m/s (10")
- 2 lengths: 101.6 mm (4″) and 254 mm (10")
- No membrane
- No gas pressure reduction
- Connection: 1/2" NPT thread-o-let
- Installation on depressurized line
GENIE GPSD sampling probe
- Fixed probe for gas application and small diameter pipes
- Maximum working pressure: 206.8 barg (3000 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 132°C with type 7 membrane
- Length: 50.8 mm (2″)
- Separation of liquids by membrane on probe tip
- Relaxation possible as an option
- Connection: 3/4" NPT thread-o-let
- Installation of housing on depressurized line
- Extraction and insertion of probe under pressure for maintenance
GENIE GP2 sampling probe
- Fixed probe for gas application and small diameter pipes
- Maximum Working Pressure: 241.3 barg (3500 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- -37°C to 149°C with diaphragm type 7
- 3 Lengths: 101.6 mm (4″); 177.8 mm (7″); 228.6 mm (9")
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 3/4" or 1″ NPT thread-o-let
- Installation of housing on depressurized line
- Extraction and insertion of probe under pressure for maintenance
GENIE GPR sampling probe
- Fixed probe for gas application
- Maximum Working Pressure: 241.3 barg (3500 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 132°C with type 7 membrane
- 3 Lengths: 101.6 mm (4″); 177.8 mm (7″); 228.6 mm (9")
- Separation of liquids by membrane on probe tip
- Integrated gas pressure reduction
- Connection: 3/4" or 1″ NPT thread-o-let
- Installation of housing on depressurized line
- Extraction and insertion of probe under pressure for maintenance
GENIE 701 sampling probe
- Portable probe for gas application
- Maximum working pressure: 206.8 barg (3000 psig)
- Maximum temperature: -37°C to 85°C with diaphragm type 6
- Adjustable length up to a maximum length of 304.8 mm (12″)
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 1/2″ NPT full opening threaded valve
- Insertable/retractable probe under pressure
GENIE 702 sampling probe
- Fixed probe for gas application
- Maximum Working Pressure: 241.3 barg (3500 psig)
- Maximum temperature :
- -37.2°C to 85°C with type 6 membrane
- -37.2°C to 149°C with Type 7 membrane
- Maximum flow rate: 2.0 LPM with Type 6 diaphragm and 2.5 LPM with Type 7 diaphragm
- Lengths on request from 304.8 mm (12″) to 3048 mm (120")
- Separation of liquids by membrane on probe tip
- Connection: 3/4″ NPT full-opening threaded or flanged valve
- Insertable/retractable probe under pressure
- Ball valve to partially retract the probe
GENIE 750 sampling rod
- Fixed probe for gas application
- Maximum Working Pressure: 258.6 barg (3750 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 149°C with type 7 membrane
- Maximum flow rate: 1.6 LPM with diaphragm type 6 and 3.4 LPM with diaphragm type 7
- 6 lengths: 203.22 mm (8″), 304.8 mm (12″), 457.2 mm (18″), 609.6 mm (24″), 914.4 mm (36″) or 1219.2 mm (48″)
- Separation of liquids by membrane on probe tip
- No gas pressure reduction
- Connection: 3/4″, 1″, or 1.5″ NPT full opening threaded or flanged valve
- Insertable/retractable probe under pressure
GENIE 755 sampling rod
- Fixed probe for gas application
- Maximum Working Pressure: 258.6 barg (3750 psig)
- Maximum temperature :
- -37°C to 85°C with type 6 membrane
- Up to 132°C with type 7 membrane
- 6 lengths: 203.22 mm (8″), 304.8 mm (12″), 457.2 mm (18″), 609.6 mm (24″), 914.4 mm (36″) or 1219.2 mm (48″)
- Separation of liquids by membrane on probe tip
- Integrated gas pressure reduction
- Connection: 3/4″, 1″, or 1.5″ NPT full opening threaded or flanged valve
- Insertable/retractable probe under pressure
GENIE 760 sampling probe
- Fixed probe for gas and liquid application
- Maximum Working Pressure: 258.6 barg (3750 psig)
- Maximum temperature: -40°C to 149°C
- 6 lengths 203.22 mm (8″), 304.8 mm (12″), 457.2 mm (18″), 609.6 mm (24″), 914.4 mm (36″) or 1219.2 mm (48″)
- No membrane on probe tip
- No gas pressure reduction
- Connection: 3/4″, 1″, or 1.5″ NPT full opening threaded or flanged valve
- Insertable/retractable probe under pressure